Safe operation of battery diaphragm testing machine, these are the focus

Time:2020-01-10
Battery diaphragm tester mainly on the tensile properties of the diaphragm, the tensile strength and deformation rate, tensile force, tensile properties, heat sealing strength, roller peeling test, pants tearing force......

Battery diaphragm tester mainly on the tensile properties of the diaphragm, the tensile strength and deformation rate, tensile force, tensile properties, heat sealing strength, roller peeling test, pants tearing force, 180 degrees 90 degrees stripping, stripping, rope tensile force, compression test, bending test, shear test, bursting test, such as complete different test, according to the customer's demand is different, Can install different fixture, wide sample fixture, Japanese fixture, British fixture and so on to meet the standards of many countries.

The battery diaphragm testing machine adopts dc servo motor and speed control system integrated structure to drive the synchronous belt reducer, which drives the screw pair to load after deceleration. The electrical part includes load measurement system and deformation measurement system. All the control parameters and measurement results can be displayed in real time on the large LCD screen. And has overload protection, displacement measurement and other functions.

Safe operation of battery diaphragm testing machine, these are the focus

1. try not to place some heavy, high hardness objects around the testing machine, in order to prevent hard objects to impact the lifting screw;

2. to know overload, super speed work, will only bring to the testing machine & LDquo; Deadly & throughout; Harm, but also to the results of the future test will affect, so we should put an end to such a wrong operation;

3. microcomputer and testing machine connection steps must be carried out in accordance with the instructions, or let the experience of old operators for the correct connection; Deadly & throughout; Harm, but also to the results of the future test will affect, so we should put an end to such a wrong operation;

4. replacement fixture must choose the correct fixture, in order to avoid affecting the results of the test;

5. Testing machine fixture moving up and down to smooth, avoid friction and the machine itself, each test must check the fixture screw tightness;

6. Test machine results need to print, check whether the printer is available;

7. Finally, we must click on the computer to close the button, remember not to cut off the power switch directly (and close the computer a reason).

8. After use, remove the fixture and the object to be measured for the convenience of next use.